SPC Modular Syringe Pump with up to 8 Pump Units
SPC is a modular syringe pump system designed for precise infusion and withdrawal of liquids in laboratories, research and other applications requiring accurate control at very low flow rates. The system is designed for laboratory use and is not intended for medical applications.
The SPC syringe pump consists of a separate control unit with a 7" touchscreen that can be connected to up to 8 individual pump units. The controller displays the operating parameters and status of the connected pump units and allows them to be controlled individually or as part of a coordinated pumping sequence.
SPC supports both infusion and withdrawal and, depending on the selected pump unit, can be used with standard syringes, glass syringes and microsyringes in various sizes. The modular design makes the syringe pump suitable for applications such as research, microfluidics, chemical experimental setups and automated laboratory processes where multiple liquids need to be dispensed precisely and under controlled conditions.
Key Features
- Modular syringe pump system with 1-8 individual pump units.
- 7" industrial colour LCD touchscreen.
- Supports infusion, withdrawal and combined infusion/withdrawal sequences.
- Independent working mode: Each pump unit can operate independently and perform infusion or withdrawal at different flow rates, either simultaneously or at different times.
- Logic working mode: The pump units can operate in a time-coordinated sequence with different infusion and withdrawal ratios.
- Online flow rate adjustment allows the flow rate to be changed while the pump is running.
- Intelligent calibration and online volume fine-tuning for precise liquid dispensing.
- Real-time monitoring of the operating status of each pump unit.
- Individual alarms for each pump unit.
- Adjustable back distance from 0.01-5 mm can help reduce air bubbles in the syringe and improve volumetric accuracy.
- Fast forward and reverse functions facilitate syringe installation, filling and flushing.
- RS232/RS485 communication with Modbus RTU for external control.
- Power-off memory retains the most recently used operating parameters.
Flow Data
The flow rate depends on the syringe inner diameter and the selected linear speed. SPC has a linear speed range of 1 µm/min to 132 mm/min. The flow rate is calculated from the linear speed and the internal cross-sectional area of the syringe.
The flow data below apply to the specified syringe sizes and inner diameters.
Standard Syringes
| Syringe Size |
Inner Diameter |
Min. Flow Rate |
Max. Flow Rate |
| 1 mL |
4.70 mm |
0.0174 µL/min |
2.29 mL/min |
| 2 mL |
9.70 mm |
0.0739 µL/min |
9.755 mL/min |
| 5 mL |
12.48 mm |
0.1223 µL/min |
16.147 mL/min |
| 10 mL |
15.89 mm |
0.1983 µL/min |
26.177 mL/min |
| 20 mL |
20.00 mm |
0.3142 µL/min |
41.469 mL/min |
| 30 mL |
22.50 mm |
0.3976 µL/min |
52.484 mL/min |
| 50 mL |
28.90 mm |
0.6560 µL/min |
86.588 mL/min |
Glass Syringes
| Syringe Size |
Inner Diameter |
Min. Flow Rate |
Max. Flow Rate |
| 250 µL |
2.30 mm |
0.0042 µL/min |
0.5484 mL/min |
| 500 µL |
3.25 mm |
0.0083 µL/min |
1.095 mL/min |
| 1 mL |
4.60 mm |
0.0167 µL/min |
2.2033 mL/min |
| 2.5 mL |
7.28 mm |
0.0416 µL/min |
5.4944 mL/min |
| 5 mL |
10.30 mm |
0.0833 µL/min |
10.9986 mL/min |
| 10 mL |
14.57 mm |
0.1667 µL/min |
22.0081 mL/min |
| 25 mL |
23.00 mm |
0.4166 µL/min |
54.9859 mL/min |
| 50 mL |
32.57 mm |
0.8321 µL/min |
109.976 mL/min |
Microsyringes
| Syringe Size |
Inner Diameter |
Min. Flow Rate |
Max. Flow Rate |
| 0.5 µL |
0.10 mm |
0.008 nL/min |
1.0296 µL/min |
| 1 µL |
0.15 mm |
0.018 nL/min |
2.3232 µL/min |
| 2 µL |
0.20 mm |
0.031 nL/min |
4.1448 µL/min |
| 5 µL |
0.35 mm |
0.096 nL/min |
12.6984 µL/min |
| 10 µL |
0.50 mm |
0.2 nL/min |
25.8 µL/min |
| 25 µL |
0.80 mm |
0.5 nL/min |
66.4 µL/min |
| 50 µL |
1.10 mm |
1 nL/min |
125.4 µL/min |
| 100 µL |
1.60 mm |
2 nL/min |
265.4 µL/min |
The specified flow ranges are based on the syringe inner diameters shown above. When other syringes are used, the actual flow rate depends on the syringe inner diameter and the selected linear speed.
Technical Specifications
- Operating functions: Infusion, withdrawal, infusion/withdrawal and withdrawal/infusion.
- Number of pump units: 1-8.
- Compatible syringe sizes:
- ZU-I: 0.5 µL-60 mL.
- ZU-I-G1: 250 µL-25 mL.
- ZU-I-G2: 50 mL.
- Syringe selection: Preset syringes from major manufacturers are available. Users can select the manufacturer, type and size, or manually define the syringe inner diameter (ID).
- Linear speed range: 1 µm/min-132 mm/min.
- Minimum linear speed: 1 µm/min.
- Maximum linear force: ≥16 kgf.
- Maximum stroke: 90 mm.
- Stroke resolution: 0.078 µm/microstep.
- Accuracy: Error ≤ ±0.5% at a stroke length of ≥30% of the maximum stroke.
- Back distance: 0.01-5 mm.
- Working modes: Independent working mode and Logic working mode.
- Memory: Up to 5 stored parameter sets per working mode.
- Display: Industrial 7" colour LCD.
- Operation: Touchscreen.
- Power-off memory: Retains the most recently used operating parameters and restores them when the system is restarted.
- External control signals: Start/stop, active switch signal (5-24 V), all start/stop signal and passive switch signal, e.g. foot switch.
- Communication interface: RS232/RS485 with Modbus RTU.
- Controller power supply: DC 5 V / 10 W.
- Pump unit power supply: DC 24 V / 30 W.
- Operating temperature: 0-40 °C.
- Relative humidity: <80%.
- IP rating: IP31.
- Controller dimensions: 240 × 221 × 111 mm.
- Pump unit dimensions: 257 × 110 × 131 mm.
- Controller weight: 2.0 kg.
- Pump unit weight: 3.0 kg.
Warranty and Documentation
- Supplied with an English user manual.
- The product datasheet can be downloaded from the product page.